{"product_id":"1-1-4-nm-lt-str-conn","title":"1-1\/4 NM LT STR CONN","description":"\u003ch3 data-section-id=\"1idzntm\" data-start=\"48\" data-end=\"65\"\u003e🔌 What it is\u003c\/h3\u003e\n\u003cp data-start=\"66\" data-end=\"229\"\u003eA \u003cstrong data-start=\"68\" data-end=\"127\"\u003e1-1\/4 inch non-metallic liquid-tight straight connector\u003c\/strong\u003e used to terminate flexible conduit into an electrical box or equipment enclosure in a straight entry.\u003c\/p\u003e\n\u003chr data-start=\"231\" data-end=\"234\"\u003e\n\u003ch3 data-section-id=\"9f6580\" data-start=\"236\" data-end=\"267\"\u003e🧾 What the shorthand means\u003c\/h3\u003e\n\u003cul data-start=\"268\" data-end=\"491\"\u003e\n\u003cli data-section-id=\"1k180lk\" data-start=\"268\" data-end=\"337\"\u003e\n\u003cstrong data-start=\"270\" data-end=\"280\"\u003e1-1\/4\"\u003c\/strong\u003e → conduit trade size (fits 1.25-inch flexible conduit)\u003c\/li\u003e\n\u003cli data-section-id=\"18erqkp\" data-start=\"338\" data-end=\"409\"\u003e\n\u003cstrong data-start=\"340\" data-end=\"349\"\u003eNM LT\u003c\/strong\u003e → non-metallic liquid-tight (flexible PVC conduit system)\u003c\/li\u003e\n\u003cli data-section-id=\"1beym36\" data-start=\"410\" data-end=\"466\"\u003e\n\u003cstrong data-start=\"412\" data-end=\"419\"\u003eSTR\u003c\/strong\u003e → straight connector (no bend, direct entry)\u003c\/li\u003e\n\u003cli data-section-id=\"1evpuqd\" data-start=\"467\" data-end=\"491\"\u003e\n\u003cstrong data-start=\"469\" data-end=\"477\"\u003eCONN\u003c\/strong\u003e → connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"493\" data-end=\"496\"\u003e\n\u003ch3 data-section-id=\"1xn4pf1\" data-start=\"498\" data-end=\"516\"\u003e⚡ What it does\u003c\/h3\u003e\n\u003cp data-start=\"517\" data-end=\"541\"\u003eThis fitting is used to:\u003c\/p\u003e\n\u003cul data-start=\"542\" data-end=\"827\"\u003e\n\u003cli data-section-id=\"b3p5hs\" data-start=\"542\" data-end=\"619\"\u003eConnect \u003cstrong data-start=\"552\" data-end=\"592\"\u003eliquid-tight flexible conduit (LFNC)\u003c\/strong\u003e to electrical enclosures\u003c\/li\u003e\n\u003cli data-section-id=\"ia80pq\" data-start=\"620\" data-end=\"683\"\u003eProvide a \u003cstrong data-start=\"632\" data-end=\"681\"\u003esealed, weather-resistant conduit entry point\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"erzwxi\" data-start=\"684\" data-end=\"762\"\u003eAllow wiring to pass \u003cstrong data-start=\"707\" data-end=\"760\"\u003estraight into a junction box, panel, or equipment\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vn09iw\" data-start=\"763\" data-end=\"827\"\u003eProtect conductors from \u003cstrong data-start=\"789\" data-end=\"827\"\u003emoisture, oil, dust, and vibration\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"829\" data-end=\"832\"\u003e\n\u003ch3 data-section-id=\"1a97u8\" data-start=\"834\" data-end=\"853\"\u003e🏠 Typical uses\u003c\/h3\u003e\n\u003cul data-start=\"854\" data-end=\"1035\"\u003e\n\u003cli data-section-id=\"19z8nsp\" data-start=\"854\" data-end=\"876\"\u003eOutdoor HVAC units\u003c\/li\u003e\n\u003cli data-section-id=\"r5a8ut\" data-start=\"877\" data-end=\"907\"\u003ePump and motor connections\u003c\/li\u003e\n\u003cli data-section-id=\"1rzadjr\" data-start=\"908\" data-end=\"934\"\u003ePool and spa equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1ts7iec\" data-start=\"935\" data-end=\"957\"\u003eIrrigation systems\u003c\/li\u003e\n\u003cli data-section-id=\"ho81mp\" data-start=\"958\" data-end=\"982\"\u003eIndustrial machinery\u003c\/li\u003e\n\u003cli data-section-id=\"7ylsov\" data-start=\"983\" data-end=\"1035\"\u003eAny wet or damp-location electrical installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1037\" data-end=\"1040\"\u003e\n\u003ch3 data-section-id=\"1p3o9gl\" data-start=\"1042\" data-end=\"1067\"\u003e🧠 Simple explanation\u003c\/h3\u003e\n\u003cblockquote data-start=\"1068\" data-end=\"1204\"\u003e\n\u003cp data-start=\"1070\" data-end=\"1204\"\u003eThis is a \u003cstrong data-start=\"1080\" data-end=\"1203\"\u003estraight waterproof connector that attaches 1-1\/4\" flexible conduit directly into an electrical box or device enclosure\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"1206\" data-end=\"1209\"\u003e\n\u003ch3 data-section-id=\"1ioqiu6\" data-start=\"1211\" data-end=\"1230\"\u003e🔧 Key takeaway\u003c\/h3\u003e\n\u003cul data-start=\"1231\" data-end=\"1387\"\u003e\n\u003cli data-section-id=\"vkind0\" data-start=\"1231\" data-end=\"1289\"\u003eUsed with \u003cstrong data-start=\"1243\" data-end=\"1289\"\u003eliquid-tight flexible non-metallic conduit\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"z5k03y\" data-start=\"1290\" data-end=\"1334\"\u003eProvides \u003cstrong data-start=\"1301\" data-end=\"1334\"\u003esealed straight conduit entry\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7io14x\" data-start=\"1335\" data-end=\"1387\"\u003eCommon in \u003cstrong data-start=\"1347\" data-end=\"1387\"\u003eoutdoor and equipment wiring systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ARLINGTON INDUSTRIES, INC.","offers":[{"title":"Default Title","offer_id":52411468087585,"sku":"NMLT125","price":7.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/1905\/1041\/files\/download_12_5ef622f7-0697-4534-9910-d1e215751bc7.jpg?v=1777572990","url":"https:\/\/standardvmi.com\/products\/1-1-4-nm-lt-str-conn","provider":"Standard Plumbing Supply","version":"1.0","type":"link"}