{"product_id":"11-1-gpm-dv-cond-tnklss-w-pump","title":"11.1 GPM DV COND TNKLSS W\/PUMP","description":"\u003cp data-start=\"254\" data-end=\"632\"\u003eThe \u003cstrong data-start=\"258\" data-end=\"280\"\u003eNoritz NRCR111DVNG\u003c\/strong\u003e is a high-efficiency residential \u003cstrong data-start=\"314\" data-end=\"350\"\u003econdensing tankless water heater\u003c\/strong\u003e designed to deliver continuous hot water on demand. It incorporates an integrated recirculation pump and advanced heat-exchanger technology to improve efficiency, reduce water waste, and provide faster hot-water delivery throughout the home. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"634\" data-end=\"637\"\u003e\n\u003ch2 data-section-id=\"z5y173\" data-start=\"639\" data-end=\"670\"\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"672\" data-end=\"1253\"\u003e\n\u003cli data-section-id=\"13046fl\" data-start=\"672\" data-end=\"746\"\u003e\n\u003cstrong data-start=\"674\" data-end=\"692\"\u003eMaximum Input:\u003c\/strong\u003e 199,900 BTU\/h \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1uwjuam\" data-start=\"747\" data-end=\"820\"\u003e\n\u003cstrong data-start=\"749\" data-end=\"767\"\u003eMinimum Input:\u003c\/strong\u003e 18,000 BTU\/h \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kxapla\" data-start=\"821\" data-end=\"889\"\u003e\n\u003cstrong data-start=\"823\" data-end=\"845\"\u003eMaximum Flow Rate:\u003c\/strong\u003e ~11.1 GPM (depending on temperature rise)\u003c\/li\u003e\n\u003cli data-section-id=\"nynhxo\" data-start=\"890\" data-end=\"915\"\u003e\n\u003cstrong data-start=\"892\" data-end=\"901\"\u003eFuel:\u003c\/strong\u003e Natural Gas\u003c\/li\u003e\n\u003cli data-section-id=\"hlcr40\" data-start=\"916\" data-end=\"1022\"\u003e\n\u003cstrong data-start=\"918\" data-end=\"932\"\u003eVent Type:\u003c\/strong\u003e Direct Vent (PVC, CPVC, or polypropylene venting) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1gb61mv\" data-start=\"1023\" data-end=\"1103\"\u003e\n\u003cstrong data-start=\"1025\" data-end=\"1048\"\u003eRecirculation Pump:\u003c\/strong\u003e Built-in internal pump for faster hot water delivery\u003c\/li\u003e\n\u003cli data-section-id=\"39gq3f\" data-start=\"1104\" data-end=\"1161\"\u003e\n\u003cstrong data-start=\"1106\" data-end=\"1125\"\u003eHeat Exchanger:\u003c\/strong\u003e High-efficiency condensing design\u003c\/li\u003e\n\u003cli data-section-id=\"1fa2zw5\" data-start=\"1162\" data-end=\"1253\"\u003e\n\u003cstrong data-start=\"1164\" data-end=\"1191\"\u003eElectrical Requirement:\u003c\/strong\u003e 120 V AC power supply \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1255\" data-end=\"1258\"\u003e\n\u003ch2 data-section-id=\"1m5op72\" data-start=\"1260\" data-end=\"1299\"\u003ePhysical \u0026amp; Connection Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1301\" data-end=\"1685\"\u003e\n\u003cli data-section-id=\"1a1v857\" data-start=\"1301\" data-end=\"1361\"\u003e\n\u003cstrong data-start=\"1303\" data-end=\"1314\"\u003eWeight:\u003c\/strong\u003e ~73 lb \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jsat9l\" data-start=\"1362\" data-end=\"1440\"\u003e\n\u003cstrong data-start=\"1364\" data-end=\"1389\"\u003eWater Pressure Range:\u003c\/strong\u003e 15–150 psi \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15kh6ao\" data-start=\"1441\" data-end=\"1532\"\u003e\n\u003cstrong data-start=\"1443\" data-end=\"1465\"\u003eWater Connections:\u003c\/strong\u003e ¾ in. NPT inlet and outlet \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1po6jv5\" data-start=\"1533\" data-end=\"1604\"\u003e\n\u003cstrong data-start=\"1535\" data-end=\"1554\"\u003eGas Connection:\u003c\/strong\u003e ¾ in. NPT \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"e3usky\" data-start=\"1605\" data-end=\"1685\"\u003e\n\u003cstrong data-start=\"1607\" data-end=\"1633\"\u003eInternal Water Volume:\u003c\/strong\u003e ~0.85 gal \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1687\" data-end=\"1690\"\u003e\n\u003ch2 data-section-id=\"1x17iii\" data-start=\"1692\" data-end=\"1715\"\u003ePerformance Features\u003c\/h2\u003e\n\u003cul data-start=\"1717\" data-end=\"2233\"\u003e\n\u003cli data-section-id=\"topc4j\" data-start=\"1717\" data-end=\"1808\"\u003e\n\u003cstrong data-start=\"1719\" data-end=\"1745\"\u003eCondensing Technology:\u003c\/strong\u003e Improves thermal efficiency and reduces exhaust temperature.\u003c\/li\u003e\n\u003cli data-section-id=\"9kql23\" data-start=\"1809\" data-end=\"1921\"\u003e\n\u003cstrong data-start=\"1811\" data-end=\"1845\"\u003eIntegrated Recirculation Pump:\u003c\/strong\u003e Allows hot water to circulate through plumbing lines to reduce wait time.\u003c\/li\u003e\n\u003cli data-section-id=\"rpd1km\" data-start=\"1922\" data-end=\"2038\"\u003e\n\u003cstrong data-start=\"1924\" data-end=\"1945\"\u003eFlexible Venting:\u003c\/strong\u003e Compatible with 2\" or 3\" PVC\/CPVC venting systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1soeruq\" data-start=\"2039\" data-end=\"2140\"\u003e\n\u003cstrong data-start=\"2041\" data-end=\"2073\"\u003eCompact Wall-Mounted Design:\u003c\/strong\u003e Saves installation space compared with traditional tank heaters.\u003c\/li\u003e\n\u003cli data-section-id=\"izin8g\" data-start=\"2141\" data-end=\"2233\"\u003e\n\u003cstrong data-start=\"2143\" data-end=\"2167\"\u003eOn-Demand Operation:\u003c\/strong\u003e Produces hot water only when needed, improving energy efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2235\" data-end=\"2238\"\u003e\n\u003ch2 data-section-id=\"164os46\" data-start=\"2240\" data-end=\"2263\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cul data-start=\"2265\" data-end=\"2443\"\u003e\n\u003cli data-section-id=\"1l0uxv0\" data-start=\"2265\" data-end=\"2305\"\u003eResidential whole-home water heating\u003c\/li\u003e\n\u003cli data-section-id=\"mmiqnp\" data-start=\"2306\" data-end=\"2339\"\u003eHomes with multiple bathrooms\u003c\/li\u003e\n\u003cli data-section-id=\"vdojmq\" data-start=\"2340\" data-end=\"2387\"\u003eRetrofit replacements for tank-type heaters\u003c\/li\u003e\n\u003cli data-section-id=\"1ook2zs\" data-start=\"2388\" data-end=\"2443\"\u003ePlumbing systems requiring recirculation capability\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"NORITZ AMERICAN CORPORATION","offers":[{"title":"Default Title","offer_id":52411112587553,"sku":"NRCR111DVNG","price":2247.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/1905\/1041\/files\/L8o_5LUz1j-dU8a0x2dojMHrFtJ9b7gbSSDzcBypr4KKpYdaMVv9J6_flhhdyFkDSgRiOxd09QDPAabJJVjufEd1Z-Nn5QUWK-IGX1KDww5mZGPKlFmtlRf4bV9Zx3nSc5KG9bLt5uQtJjpf7l_dmrV7fUZosI4aowtRzCktgOg.jpg?v=1775842467","url":"https:\/\/standardvmi.com\/products\/11-1-gpm-dv-cond-tnklss-w-pump","provider":"Standard Plumbing Supply","version":"1.0","type":"link"}