{"product_id":"30a-125-250v-3p4w-male-flanged","title":"30A 125\/250V 3P4W MALE FLANGED","description":"\u003ch2 data-section-id=\"4dmzfz\" data-start=\"0\" data-end=\"65\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3\" data-end=\"65\"\u003e30A 125\/250V 3P4W MALE FLANGED INLET (Product Description)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"67\" data-end=\"294\"\u003eA \u003cstrong data-start=\"69\" data-end=\"135\"\u003e30-amp, 125\/250-volt, 3-phase\/4-wire (3P4W) male flanged inlet\u003c\/strong\u003e is a \u003cstrong data-start=\"141\" data-end=\"185\"\u003epanel-mounted locking power inlet device\u003c\/strong\u003e used for industrial and commercial electrical systems that require a secure, high-capacity connection point.\u003c\/p\u003e\n\u003chr data-start=\"296\" data-end=\"299\"\u003e\n\u003ch3 data-section-id=\"1gh5l1n\" data-start=\"301\" data-end=\"328\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"305\" data-end=\"328\"\u003eProduct Description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"329\" data-end=\"528\"\u003eThis is a \u003cstrong data-start=\"339\" data-end=\"393\"\u003eheavy-duty flanged inlet (male power inlet device)\u003c\/strong\u003e rated for \u003cstrong data-start=\"404\" data-end=\"426\"\u003e30A at 125\/250V AC\u003c\/strong\u003e, designed to be mounted directly into an electrical panel, generator housing, or equipment enclosure.\u003c\/p\u003e\n\u003cp data-start=\"530\" data-end=\"661\"\u003eIt provides a \u003cstrong data-start=\"544\" data-end=\"579\"\u003esecure locking connection point\u003c\/strong\u003e for mating plugs or cords in \u003cstrong data-start=\"609\" data-end=\"635\"\u003e3-pole, 4-wire systems\u003c\/strong\u003e, typically consisting of:\u003c\/p\u003e\n\u003cul data-start=\"662\" data-end=\"752\"\u003e\n\u003cli data-section-id=\"1whp10w\" data-start=\"662\" data-end=\"691\"\u003e3 phase or hot conductors\u003c\/li\u003e\n\u003cli data-section-id=\"zjse6b\" data-start=\"692\" data-end=\"752\"\u003e1 neutral or ground conductor (depending on configuration)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"754\" data-end=\"972\"\u003eThe \u003cstrong data-start=\"758\" data-end=\"776\"\u003eflanged design\u003c\/strong\u003e allows the inlet to be bolted securely to a flat surface, ensuring stability in \u003cstrong data-start=\"857\" data-end=\"899\"\u003ehigh-vibration or outdoor environments\u003c\/strong\u003e such as generators, construction equipment, and temporary power systems.\u003c\/p\u003e\n\u003cp data-start=\"974\" data-end=\"1133\"\u003eCommon industry equivalents include \u003cstrong data-start=\"1010\" data-end=\"1056\"\u003eNEMA L14-30 or L15-30 style flanged inlets\u003c\/strong\u003e, depending on exact pin configuration. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1135\" data-end=\"1138\"\u003e\n\u003ch3 data-section-id=\"1reerq7\" data-start=\"1140\" data-end=\"1166\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1144\" data-end=\"1166\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1167\" data-end=\"1493\"\u003e\n\u003cli data-section-id=\"1tp9r14\" data-start=\"1167\" data-end=\"1188\"\u003e\n\u003cstrong data-start=\"1169\" data-end=\"1182\"\u003eAmperage:\u003c\/strong\u003e 30A\u003c\/li\u003e\n\u003cli data-section-id=\"1wpae4q\" data-start=\"1189\" data-end=\"1217\"\u003e\n\u003cstrong data-start=\"1191\" data-end=\"1203\"\u003eVoltage:\u003c\/strong\u003e 125\/250V AC\u003c\/li\u003e\n\u003cli data-section-id=\"i18zbe\" data-start=\"1218\" data-end=\"1276\"\u003e\n\u003cstrong data-start=\"1220\" data-end=\"1236\"\u003eSystem Type:\u003c\/strong\u003e 3-phase or split-phase capable (3P4W)\u003c\/li\u003e\n\u003cli data-section-id=\"1u7q106\" data-start=\"1277\" data-end=\"1314\"\u003e\n\u003cstrong data-start=\"1279\" data-end=\"1297\"\u003eConfiguration:\u003c\/strong\u003e 3-pole, 4-wire\u003c\/li\u003e\n\u003cli data-section-id=\"1bouz3y\" data-start=\"1315\" data-end=\"1359\"\u003e\n\u003cstrong data-start=\"1317\" data-end=\"1335\"\u003eMounting Type:\u003c\/strong\u003e Flanged (panel mount)\u003c\/li\u003e\n\u003cli data-section-id=\"15qo1wa\" data-start=\"1360\" data-end=\"1427\"\u003e\n\u003cstrong data-start=\"1362\" data-end=\"1382\"\u003eConnector Style:\u003c\/strong\u003e Locking inlet (male panel inlet interface)\u003c\/li\u003e\n\u003cli data-section-id=\"vhvg7t\" data-start=\"1428\" data-end=\"1493\"\u003e\n\u003cstrong data-start=\"1430\" data-end=\"1443\"\u003eMaterial:\u003c\/strong\u003e Industrial-grade nylon or thermoplastic housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1495\" data-end=\"1498\"\u003e\n\u003ch3 data-section-id=\"pm8yra\" data-start=\"1500\" data-end=\"1520\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1504\" data-end=\"1520\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1521\" data-end=\"1819\"\u003e\n\u003cli data-section-id=\"ctwtzd\" data-start=\"1521\" data-end=\"1586\"\u003eSecure \u003cstrong data-start=\"1530\" data-end=\"1586\"\u003elocking connection prevents accidental disconnection\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zowfrb\" data-start=\"1587\" data-end=\"1649\"\u003eSupports \u003cstrong data-start=\"1598\" data-end=\"1649\"\u003ehigh-load industrial and generator applications\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qkyr76\" data-start=\"1650\" data-end=\"1708\"\u003eFlanged mounting ensures \u003cstrong data-start=\"1677\" data-end=\"1708\"\u003estrong mechanical stability\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"116mukv\" data-start=\"1709\" data-end=\"1762\"\u003eDesigned for \u003cstrong data-start=\"1724\" data-end=\"1762\"\u003econtinuous-duty electrical service\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15ys4ia\" data-start=\"1763\" data-end=\"1819\"\u003eResistant to vibration, impact, and outdoor exposure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1821\" data-end=\"1824\"\u003e\n\u003ch3 data-section-id=\"jq6nn9\" data-start=\"1826\" data-end=\"1854\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1830\" data-end=\"1854\"\u003eTypical Applications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1855\" data-end=\"2040\"\u003e\n\u003cli data-section-id=\"jt8fuv\" data-start=\"1855\" data-end=\"1890\"\u003ePortable and standby generators\u003c\/li\u003e\n\u003cli data-section-id=\"12qw63f\" data-start=\"1891\" data-end=\"1928\"\u003eIndustrial machinery power inputs\u003c\/li\u003e\n\u003cli data-section-id=\"15vlii4\" data-start=\"1929\" data-end=\"1974\"\u003eConstruction site temporary power systems\u003c\/li\u003e\n\u003cli data-section-id=\"14406l3\" data-start=\"1975\" data-end=\"2010\"\u003eCommercial equipment enclosures\u003c\/li\u003e\n\u003cli data-section-id=\"iw7fvs\" data-start=\"2011\" data-end=\"2040\"\u003ePower distribution panels\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEVITON MANUFACTURING CO","offers":[{"title":"Default Title","offer_id":52411456815393,"sku":"CP11293","price":52.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/1905\/1041\/files\/download_5_f35f5127-df8f-4383-8831-c7c25a14f3d5.webp?v=1777662466","url":"https:\/\/standardvmi.com\/products\/30a-125-250v-3p4w-male-flanged","provider":"Standard Plumbing Supply","version":"1.0","type":"link"}