{"product_id":"dmm-temp-mfd-b-light","title":"DMM, TEMP, MFD, B\/LIGHT","description":"\u003cu\u003eFieldpiece\u003c\/u\u003e Classic Style Digital Multimeter with Temperature\u003cbr\u003eSKU: LT17A\u003cbr\u003e\u003cbr\u003eThe LT17A is a manual ranger that covers most of the parameters and ranges you need for most HVAC\/R applications. The LT17A meter measures current, resistance, voltage, capacitance, frequency, continuity, and temperature. Test leads store in the meter body and, with the probe tips removed, connect the LT17A to Fieldpiece accessory heads. The body is made out of durable ABS plastic and comes with a bright blue backlight for poorly lit test areas. Get great accuracy using the included k-type thermocouple and an easily accessible temperature calibration pot.\u003cbr\u003eThe LT17A is a manual ranging DMM that comes with an amp clamp and k-type thermocouple. Use the MIN\/MAX function to record highs and lows. The continuity beeper tells you if a circuit is open or closed. Operation of the LT17A is easy. Simply select a range and test.\u003cbr\u003eFeatures and Benefits:\u003cbr\u003eWorks with Fieldpiece Accessory Heads\u003cbr\u003eThere is a Fieldpiece accessory head available for just about any job. There are heads to measure temperature, superheat, subcooling, RH%, wet bulb, dew point, vacuum (microns of mercury), manometer (inches of water column), amps AC\u0026amp;DC, high voltage, CO, %CO2, air velocity, and many more.\u003cbr\u003eContinuity Indicator\u003cbr\u003eIf you were doing lab testing, these features would probably drive you crazy. We've heard from more than one HVAC\/R veteran that these features really remind you of what you're doing and they've avoided potentially dangerous situations in the field. The Hi-V LED and beeper let you know when you've hooked up to a circuit over 30V. The continuity LED and beeper tells you if a circuit is open or closed.\u003cbr\u003e400AAC\u003cbr\u003eUsing the detachable test leads and the accessory head amp clamp, read 0-400 amps directly on your meter.\u003cbr\u003eCapacitance (MFD)\u003cbr\u003eMeasure microfarads on motor-run and motor-start capacitors using this range. Disconnect the capacitor from power first. Short the terminals to discharge the capacitor. Disconnect any resistors that might be between the terminals of the capacitor and measure to check for degradation.\u003cbr\u003eMicroamps DC - Flame Rectification Tests\u003cbr\u003eThe most common \"no heat\" call has to do with a malfunctioning flame sensing diode. Simply turn the meter to microamps DC, hook up, and see if the flame sensing rod is functioning properly. Frequency Measure from 10Hz to 40kHz using this range with 1 Hz resolution\u003cbr\u003eSilicone Leads with Detachable Probe Tips\u003cbr\u003eBecause the wire insulation is silicone, the leads stay flexible in cold weather and will not melt if bumped by a soldering iron. When testing electrical circuits with two hands, there is a risk that a careless mistake may complete a circuit through your body and potentially cause death or injury. Use the either probe clip on rubber boot to connect and firmly hold the V lead in place, detach the COM probe tip, connect an alligator lead tip to COM and ground, and perform a one-hand test more easily than most meters on the market. Built-in lead storage makes it easy to keep everything together from job to job.\u003cbr\u003eTilt Stand and Magnetic Hanger\u003cbr\u003eTechnicians enjoy the magnetic hanger because it keeps the meter out of the way while testing. The LT17A includes the magnet and a tilt stand to give you a choice in the way you want to use it.\u003cbr\u003eBright Blue Backlight\u003cbr\u003eEasily read the display in overcast conditions or in dimly lit areas.\u003cbr\u003eMAX\/MIN hold\u003cbr\u003eRecord the minimum or maximum reading during a measurement. To exit the MIN\/MAX function, hold the button for more than 2 seconds\u003cbr\u003eMore Features:\u003cul\u003e\n\u003cli\u003eVolts AC\u003c\/li\u003e\n\u003cli\u003eVolts DC\u003c\/li\u003e\n\u003cli\u003eResistance (Ohms)\u003c\/li\u003e\n\u003cli\u003eDiode Test\u003c\/li\u003e\n\u003cli\u003eRugged ABS case with rubber boot\u003c\/li\u003e\n\u003cli\u003eFits naturally in your hand despite classic design\u003c\/li\u003e\n\u003cli\u003eAuto power-off (APO) to conserve battery life\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eCompetitive Advantages:\u003cbr\u003eThe testing capability packed into this classic style meter is its main competitive advantage. In addition to all of the ranges, it has direct temperature measurement and it works with all of Fieldpiece's accessory head instruments to make it one of the most complete classic style meters available for HVAC\/R. Add to that the fact that the classic design still fits naturally in your hand and comes standard with a rugged rubber boot.\u003cbr\u003eWhat's Included:\u003cul\u003e\n\u003cli\u003eClassic Style Clamp Meter with Temperature - LT17A\u003c\/li\u003e\n\u003cli\u003eDeluxe Silicone Test Leads - ADLS2\u003c\/li\u003e\n\u003cli\u003eShort Alligator Lead Extensions - ASA2\u003c\/li\u003e\n\u003cli\u003e400A Amp Clamp Accessory - ACH4\u003c\/li\u003e\n\u003cli\u003eWrap Tab Bead Tip Thermocouple - ATB1\u003c\/li\u003e\n\u003cli\u003eMail Pouch-Style Instrument Case - ANC5\u003c\/li\u003e\n\u003cli\u003e9V battery (installed)\u003c\/li\u003e\n\u003cli\u003eOperator's manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eAdditional Specifications:\u003cbr\u003eDC voltage\u003cul\u003e\n\u003cli\u003eRanges: 200mV, 2000mV, 20V, 200V, 600V\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1mV\u003c\/li\u003e\n\u003cli\u003eAccuracy: 0.5%?1\u003c\/li\u003e\n\u003cli\u003eInput impedence: 10 milliohm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eAC voltage (50Hz-500Hz)\u003cul\u003e\n\u003cli\u003eRanges: 200mV, 2000mV, 20V, 200V, 600V\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1mV\u003c\/li\u003e\n\u003cli\u003eAccuracy: 1.2%?4(200mV to 20V ranges), 2%?4(200V, 600V ranges) Input impedence: 10 milliohm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eDC Current (through meter)\u003cul\u003e\n\u003cli\u003eRanges: 200 micro A, 20mA, 200mA\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1 micro A\u003c\/li\u003e\n\u003cli\u003eAccuracy: 1.0%?1\u003c\/li\u003e\n\u003cli\u003eVoltage burden: 800mV\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eAC Current (through meter)\u003cul\u003e\n\u003cli\u003eRanges: 200 micro A, 20mA, 200mA\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1 micro A\u003c\/li\u003e\n\u003cli\u003eAccuracy: 1.5%?4\u003c\/li\u003e\n\u003cli\u003eVoltage burden: 800mV\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eFrequency (autoranging)\u003cul\u003e\n\u003cli\u003eRange: 10Hz to 40KHz\u003c\/li\u003e\n\u003cli\u003eResolution: 1Hz\u003c\/li\u003e\n\u003cli\u003eSensitivity: 3.5V rms min\u003c\/li\u003e\n\u003cli\u003eAccuracy: 0.1%? 3\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eResistance (ohms)\u003cul\u003e\n\u003cli\u003eRanges: 200 ohms, 2 k ohms, 200k ohms, 20M ohms\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1 ohm\u003c\/li\u003e\n\u003cli\u003eAccuracy: 1.0%?4 (200 ohm to 200k ohm ranges), 2.0%?4 (20M ohm range)\u003c\/li\u003e\n\u003cli\u003eOpen circuit voltage: 0.3VDC typical, (3.0VDC on 200 ohm)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eDiode test\u003cul\u003e\n\u003cli\u003eAccuracy: 1.5%?3\u003c\/li\u003e\n\u003cli\u003eTest current: Approx. 1.0mA\u003c\/li\u003e\n\u003cli\u003eOpen circuit voltage: 3.0VDC typical\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eCapacitance (MFD)\u003cul\u003e\n\u003cli\u003eRanges: 200 micro F, 2k micro F, 20k micro F\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1 micro F\u003c\/li\u003e\n\u003cli\u003eAccuracy: 4%?10\u003c\/li\u003e\n\u003cli\u003eTest frequency: 21Hz\u003c\/li\u003e\n\u003cli\u003eTest voltage: \u0026lt;3.0V\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eTemperature\u003cul\u003e\n\u003cli\u003eRanges: -30 to 1400?F (-34 to 750?C)\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1?F\/?C\u003c\/li\u003e\n\u003cli\u003eAccuracy: ?1?F; 32 to 120?F (?0.5?C; 0 to 48?C), ?1.0%+1.5?F; -4 to 750?F (?1.0%+1.0?C; -20 to 399?C) ?3.0%+4?F; -30 to -4?F and 750 to 1400?F (?3.0%+2?C; -34 to -20?C and 399 to 750?C)\u003c\/li\u003e\n\u003cli\u003eSensor type: K-type thermocouple\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eField Calibration (temp offset pot)\u003cbr\u003eThe LT17A can be easily calibrated on the job. Use a bucket of ice water to have a known 32?F (0?C) temperature. With the thermocouple in the ice water, adjust the TEMP OFFSET pot on the face of the meter until it reads 32.0 (0.0).\u003cbr\u003eFuse Replacement:\u003cbr\u003eWhen only certain ranges quit working, check the fuse. Open the case and replace according to the Overload Protection values below. If that doesn't work visit our Warranty Page to check for other problems.\u003cbr\u003e","brand":"FIELDPIECE INSTRUMENTS","offers":[{"title":"Default Title","offer_id":52411356971297,"sku":"LT17A","price":189.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/1905\/1041\/files\/download_7_edb93b82-2fdc-4b21-b62f-ab8696595504.jpg?v=1778183398","url":"https:\/\/standardvmi.com\/products\/dmm-temp-mfd-b-light","provider":"Standard Plumbing Supply","version":"1.0","type":"link"}