{"product_id":"filt-nrvtoc-150-1054n","title":"Filt,NRVTOC-150 1054N","description":"\u003cp data-start=\"43\" data-end=\"221\"\u003eThe \u003cstrong data-start=\"47\" data-end=\"61\"\u003eNRVTOC-150\u003c\/strong\u003e is a \u003cstrong data-start=\"67\" data-end=\"112\"\u003ewhole-house catalytic carbon water filter\u003c\/strong\u003e designed for simple, low-maintenance removal of chlorine and chloramines—without electricity or backwashing.\u003c\/p\u003e\n\u003chr data-start=\"223\" data-end=\"226\"\u003e\n\u003ch3 data-section-id=\"1nmyna7\" data-start=\"228\" data-end=\"245\"\u003e🔧 Overview\u003c\/h3\u003e\n\u003cp data-start=\"246\" data-end=\"519\"\u003eThe \u003cstrong data-start=\"250\" data-end=\"270\"\u003eNOVO™ NRVTOC-150\u003c\/strong\u003e is a \u003cstrong data-start=\"276\" data-end=\"326\"\u003enon-regenerating valve (NRV) filtration system\u003c\/strong\u003e, meaning it operates without automatic backwash cycles or power. It’s ideal for homeowners who want \u003cstrong data-start=\"427\" data-end=\"478\"\u003ebasic whole-home filtration with minimal upkeep\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"521\" data-end=\"524\"\u003e\n\u003ch3 data-section-id=\"1g7jfts\" data-start=\"526\" data-end=\"547\"\u003e⚙️ Key Features\u003c\/h3\u003e\n\u003cul data-start=\"548\" data-end=\"1122\"\u003e\n\u003cli data-section-id=\"1e8sim3\" data-start=\"548\" data-end=\"697\"\u003e\n\u003cstrong data-start=\"550\" data-end=\"582\"\u003eCatalytic Carbon Filtration:\u003c\/strong\u003e\u003cbr data-start=\"582\" data-end=\"585\"\u003eReduces \u003cstrong data-start=\"595\" data-end=\"637\"\u003echlorine, chloramines, taste, and odor\u003c\/strong\u003e throughout the home \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"x1ittv\" data-start=\"698\" data-end=\"794\"\u003e\n\u003cstrong data-start=\"700\" data-end=\"741\"\u003eNon-Regenerating (No Power Required):\u003c\/strong\u003e\u003cbr data-start=\"741\" data-end=\"744\"\u003eNo electrical connection or programming needed\u003c\/li\u003e\n\u003cli data-section-id=\"exr5vo\" data-start=\"795\" data-end=\"879\"\u003e\n\u003cstrong data-start=\"797\" data-end=\"824\"\u003eLow Maintenance Design:\u003c\/strong\u003e\u003cbr data-start=\"824\" data-end=\"827\"\u003eNo backwashing—simple, passive filtration system\u003c\/li\u003e\n\u003cli data-section-id=\"1r49e1s\" data-start=\"880\" data-end=\"995\"\u003e\n\u003cstrong data-start=\"882\" data-end=\"910\"\u003eFactory Bypass Included:\u003c\/strong\u003e\u003cbr data-start=\"910\" data-end=\"913\"\u003eBuilt-in bypass valve for easy servicing \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"128td96\" data-start=\"996\" data-end=\"1122\"\u003e\n\u003cstrong data-start=\"998\" data-end=\"1025\"\u003eQuick Installation Kit:\u003c\/strong\u003e\u003cbr data-start=\"1025\" data-end=\"1028\"\u003eIncludes fittings and connections for faster install \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1124\" data-end=\"1127\"\u003e\n\u003ch3 data-section-id=\"nmgiu6\" data-start=\"1129\" data-end=\"1152\"\u003e📋 Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1153\" data-end=\"1715\"\u003e\n\u003cli data-section-id=\"1rn2oie\" data-start=\"1153\" data-end=\"1178\"\u003e\n\u003cstrong data-start=\"1155\" data-end=\"1165\"\u003eModel:\u003c\/strong\u003e NRVTOC-150\u003c\/li\u003e\n\u003cli data-section-id=\"reps8\" data-start=\"1179\" data-end=\"1203\"\u003e\n\u003cstrong data-start=\"1181\" data-end=\"1192\"\u003ePart #:\u003c\/strong\u003e 15054092\u003c\/li\u003e\n\u003cli data-section-id=\"441p71\" data-start=\"1204\" data-end=\"1270\"\u003e\n\u003cstrong data-start=\"1206\" data-end=\"1220\"\u003eTank Size:\u003c\/strong\u003e 10\" × 54\" \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fwco05\" data-start=\"1271\" data-end=\"1345\"\u003e\n\u003cstrong data-start=\"1273\" data-end=\"1290\"\u003eMedia Volume:\u003c\/strong\u003e 1.5 cubic feet \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ky44dw\" data-start=\"1346\" data-end=\"1446\"\u003e\n\u003cstrong data-start=\"1348\" data-end=\"1362\"\u003eFlow Rate:\u003c\/strong\u003e\n\u003cul data-start=\"1367\" data-end=\"1446\"\u003e\n\u003cli data-section-id=\"bxbkkc\" data-start=\"1367\" data-end=\"1383\"\u003ePeak: ~5 GPM\u003c\/li\u003e\n\u003cli data-section-id=\"1cq2i2y\" data-start=\"1386\" data-end=\"1446\"\u003eMax listed: ~6 GPM \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1l6nwyx\" data-start=\"1447\" data-end=\"1539\"\u003e\n\u003cstrong data-start=\"1449\" data-end=\"1469\"\u003eConnection Size:\u003c\/strong\u003e 3\/4\" (with included adapters) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tq5d95\" data-start=\"1540\" data-end=\"1612\"\u003e\n\u003cstrong data-start=\"1542\" data-end=\"1561\"\u003ePressure Range:\u003c\/strong\u003e 30–125 PSI \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"f3ple5\" data-start=\"1613\" data-end=\"1686\"\u003e\n\u003cstrong data-start=\"1615\" data-end=\"1637\"\u003eTemperature Range:\u003c\/strong\u003e 40–110°F \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mr5xe6\" data-start=\"1687\" data-end=\"1715\"\u003e\n\u003cstrong data-start=\"1689\" data-end=\"1708\"\u003ePower Required:\u003c\/strong\u003e None\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1717\" data-end=\"1720\"\u003e\n\u003ch3 data-section-id=\"1z0fp5o\" data-start=\"1722\" data-end=\"1753\"\u003e💧 Filtration Performance\u003c\/h3\u003e\n\u003cul data-start=\"1754\" data-end=\"2031\"\u003e\n\u003cli data-section-id=\"179y1k1\" data-start=\"1754\" data-end=\"1830\"\u003eUp to \u003cstrong data-start=\"1762\" data-end=\"1788\"\u003e97% chlorine reduction\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"70egea\" data-start=\"1831\" data-end=\"1947\"\u003eEffective for \u003cstrong data-start=\"1847\" data-end=\"1873\"\u003eover 1,100,000 gallons\u003c\/strong\u003e (depending on water conditions) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1x3xk3k\" data-start=\"1948\" data-end=\"2031\"\u003eImproves:\n\u003cul data-start=\"1962\" data-end=\"2031\"\u003e\n\u003cli data-section-id=\"1cug6z3\" data-start=\"1962\" data-end=\"1978\"\u003eTaste \u0026amp; odor\u003c\/li\u003e\n\u003cli data-section-id=\"ocjzpg\" data-start=\"1981\" data-end=\"2003\"\u003eSkin and hair feel\u003c\/li\u003e\n\u003cli data-section-id=\"j3mbdr\" data-start=\"2006\" data-end=\"2031\"\u003eOverall water quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2033\" data-end=\"2036\"\u003e\n\u003ch3 data-section-id=\"t2255f\" data-start=\"2038\" data-end=\"2059\"\u003e🏠 Applications\u003c\/h3\u003e\n\u003cul data-start=\"2060\" data-end=\"2241\"\u003e\n\u003cli data-section-id=\"xuwvoy\" data-start=\"2060\" data-end=\"2117\"\u003eHomes on \u003cstrong data-start=\"2071\" data-end=\"2115\"\u003ecity water (chlorine\/chloramine treated)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gy18m9\" data-start=\"2118\" data-end=\"2169\"\u003eWhole-house installation at \u003cstrong data-start=\"2148\" data-end=\"2167\"\u003emain water line\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bvck94\" data-start=\"2170\" data-end=\"2241\"\u003eIdeal where \u003cstrong data-start=\"2184\" data-end=\"2241\"\u003elow maintenance is preferred over maximum performance\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2243\" data-end=\"2246\"\u003e\n\u003ch3 data-section-id=\"15wrhjy\" data-start=\"2248\" data-end=\"2265\"\u003e🔁 Benefits\u003c\/h3\u003e\n\u003cul data-start=\"2266\" data-end=\"2436\"\u003e\n\u003cli data-section-id=\"v63zkh\" data-start=\"2266\" data-end=\"2305\"\u003e✔️ No electricity or drain required\u003c\/li\u003e\n\u003cli data-section-id=\"z30hyh\" data-start=\"2306\" data-end=\"2345\"\u003e✔️ Lower upfront and operating cost\u003c\/li\u003e\n\u003cli data-section-id=\"1prgccp\" data-start=\"2346\" data-end=\"2387\"\u003e✔️ Simple “install and forget” design\u003c\/li\u003e\n\u003cli data-section-id=\"109alzn\" data-start=\"2388\" data-end=\"2436\"\u003e✔️ Improves water quality across entire home\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2438\" data-end=\"2441\"\u003e\n\u003ch3 data-section-id=\"vjbef3\" data-start=\"2443\" data-end=\"2498\"\u003e⚠️ Important Differences (vs backwashing systems)\u003c\/h3\u003e\n\u003cul data-start=\"2499\" data-end=\"2648\"\u003e\n\u003cli data-section-id=\"1arwxmp\" data-start=\"2499\" data-end=\"2550\"\u003e❌ No self-cleaning → media will wear out faster\u003c\/li\u003e\n\u003cli data-section-id=\"uk0h4q\" data-start=\"2551\" data-end=\"2597\"\u003e❌ Lower flow capacity than powered systems\u003c\/li\u003e\n\u003cli data-section-id=\"f7x2l2\" data-start=\"2598\" data-end=\"2648\"\u003e❌ Best for \u003cstrong data-start=\"2611\" data-end=\"2646\"\u003emoderate water usage households\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Standard Plumbing Supply","offers":[{"title":"Default Title","offer_id":52493243842849,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/1905\/1041\/files\/download_9813138a-f1ea-4957-a660-add7917d3365.jpg?v=1774538351","url":"https:\/\/standardvmi.com\/products\/filt-nrvtoc-150-1054n","provider":"Standard Plumbing Supply","version":"1.0","type":"link"}