{"product_id":"ground-bar-kit-27-pos-no-14-4","title":"GROUND BAR KIT-27 POS, NO.14-4","description":"\u003ch3 data-section-id=\"1idzntm\" data-start=\"77\" data-end=\"94\"\u003e🔌 What it is\u003c\/h3\u003e\n\u003cp data-start=\"95\" data-end=\"274\"\u003eThe \u003cstrong data-start=\"99\" data-end=\"110\"\u003eEC3GB27\u003c\/strong\u003e is a \u003cstrong data-start=\"116\" data-end=\"142\"\u003eSiemens ground bar kit\u003c\/strong\u003e used inside electrical panels (load centers) to provide a dedicated point for connecting \u003cstrong data-start=\"232\" data-end=\"273\"\u003eequipment grounding conductors (EGCs)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"276\" data-end=\"370\"\u003eIt is essentially an \u003cstrong data-start=\"297\" data-end=\"323\"\u003eadd-on grounding strip\u003c\/strong\u003e for panels that need more ground terminations.\u003c\/p\u003e\n\u003chr data-start=\"372\" data-end=\"375\"\u003e\n\u003ch3 data-section-id=\"22pyni\" data-start=\"377\" data-end=\"404\"\u003e🧾 What the model means\u003c\/h3\u003e\n\u003cul data-start=\"405\" data-end=\"594\"\u003e\n\u003cli data-section-id=\"1olrq5f\" data-start=\"405\" data-end=\"453\"\u003e\n\u003cstrong data-start=\"407\" data-end=\"413\"\u003eEC\u003c\/strong\u003e → Siemens electrical accessory series\u003c\/li\u003e\n\u003cli data-section-id=\"1088wfl\" data-start=\"454\" data-end=\"511\"\u003e\n\u003cstrong data-start=\"456\" data-end=\"463\"\u003e3GB\u003c\/strong\u003e → Ground Bar family (equipment grounding bar)\u003c\/li\u003e\n\u003cli data-section-id=\"np1hcr\" data-start=\"512\" data-end=\"594\"\u003e\n\u003cstrong data-start=\"514\" data-end=\"520\"\u003e27\u003c\/strong\u003e → ~27 grounding terminal positions (varies slightly by panel application)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"596\" data-end=\"599\"\u003e\n\u003ch3 data-section-id=\"1xn4pf1\" data-start=\"601\" data-end=\"619\"\u003e⚡ What it does\u003c\/h3\u003e\n\u003cp data-start=\"620\" data-end=\"630\"\u003eThis part:\u003c\/p\u003e\n\u003cul data-start=\"631\" data-end=\"968\"\u003e\n\u003cli data-section-id=\"cceank\" data-start=\"631\" data-end=\"698\"\u003eProvides a \u003cstrong data-start=\"644\" data-end=\"681\"\u003ecommon grounding connection point\u003c\/strong\u003e inside a panel\u003c\/li\u003e\n\u003cli data-section-id=\"bwxwc3\" data-start=\"699\" data-end=\"751\"\u003eAccepts multiple \u003cstrong data-start=\"718\" data-end=\"749\"\u003ebranch circuit ground wires\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1lk0zag\" data-start=\"752\" data-end=\"820\"\u003eHelps maintain proper \u003cstrong data-start=\"776\" data-end=\"818\"\u003eneutral\/ground separation in subpanels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1a1zpxv\" data-start=\"821\" data-end=\"896\"\u003eMounts directly to Siemens load centers or designated bonding locations\u003c\/li\u003e\n\u003cli data-section-id=\"47qnx\" data-start=\"897\" data-end=\"968\"\u003eSupports \u003cstrong data-start=\"908\" data-end=\"942\"\u003ecopper and aluminum conductors\u003c\/strong\u003e (panel-dependent listing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"970\" data-end=\"1129\"\u003eThese ECGB-style bars are used for terminating grounding conductors in Siemens equipment and are UL-listed for panel use. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1131\" data-end=\"1134\"\u003e\n\u003ch3 data-section-id=\"1a97u8\" data-start=\"1136\" data-end=\"1155\"\u003e🏠 Typical uses\u003c\/h3\u003e\n\u003cul data-start=\"1156\" data-end=\"1357\"\u003e\n\u003cli data-section-id=\"1895ouv\" data-start=\"1156\" data-end=\"1186\"\u003eResidential breaker panels\u003c\/li\u003e\n\u003cli data-section-id=\"ltb6yv\" data-start=\"1187\" data-end=\"1240\"\u003eSubpanels (where separate ground bar is required)\u003c\/li\u003e\n\u003cli data-section-id=\"109ixpj\" data-start=\"1241\" data-end=\"1269\"\u003eEV circuit installations\u003c\/li\u003e\n\u003cli data-section-id=\"1vlw2ma\" data-start=\"1270\" data-end=\"1306\"\u003eHVAC \/ appliance branch circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1mfeyad\" data-start=\"1307\" data-end=\"1357\"\u003ePanel expansions needing extra ground capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1359\" data-end=\"1362\"\u003e\n\u003ch3 data-section-id=\"1p3o9gl\" data-start=\"1364\" data-end=\"1389\"\u003e🧠 Simple explanation\u003c\/h3\u003e\n\u003cblockquote data-start=\"1390\" data-end=\"1526\"\u003e\n\u003cp data-start=\"1392\" data-end=\"1526\"\u003eThis is a \u003cstrong data-start=\"1402\" data-end=\"1526\"\u003emetal strip installed inside an electrical panel where all the ground wires from circuits get connected together safely.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"SIEMENS INDUSTRY, INC.","offers":[{"title":"Default Title","offer_id":52411461337377,"sku":"EC3GB27","price":13.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/1905\/1041\/files\/shopping_3_d288e5bf-21d5-423a-a40d-39dc266d76c6.webp?v=1777654310","url":"https:\/\/standardvmi.com\/products\/ground-bar-kit-27-pos-no-14-4","provider":"Standard Plumbing Supply","version":"1.0","type":"link"}