{"product_id":"hom-indr-125a-mlo-20-40cir-wgb","title":"HOM INDR 125A MLO 20\/40CIR WGB","description":"\u003cp data-start=\"0\" data-end=\"40\"\u003e\u003cstrong data-start=\"0\" data-end=\"40\"\u003eHOM2040L125PGC – Product Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"42\" data-end=\"79\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\" role=\"button\" tabindex=\"0\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D Homeline HOM2040L125PGC\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1idzntm\" data-start=\"81\" data-end=\"98\"\u003e🔌 What it is\u003c\/h3\u003e\n\u003cp data-start=\"99\" data-end=\"265\"\u003eA \u003cstrong data-start=\"101\" data-end=\"157\"\u003eSquare D Homeline indoor load center \/ breaker panel\u003c\/strong\u003e rated for \u003cstrong data-start=\"168\" data-end=\"180\"\u003e125 amps\u003c\/strong\u003e, with \u003cstrong data-start=\"187\" data-end=\"222\"\u003e20 spaces and up to 40 circuits\u003c\/strong\u003e, configured as a \u003cstrong data-start=\"240\" data-end=\"264\"\u003emain lug load center\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"267\" data-end=\"270\"\u003e\n\u003ch3 data-section-id=\"22pyni\" data-start=\"272\" data-end=\"299\"\u003e🧾 What the model means\u003c\/h3\u003e\n\u003cul data-start=\"300\" data-end=\"595\"\u003e\n\u003cli data-section-id=\"81nfn3\" data-start=\"300\" data-end=\"338\"\u003e\n\u003cstrong data-start=\"302\" data-end=\"309\"\u003eHOM\u003c\/strong\u003e → Square D Homeline series\u003c\/li\u003e\n\u003cli data-section-id=\"h788kl\" data-start=\"339\" data-end=\"369\"\u003e\n\u003cstrong data-start=\"341\" data-end=\"347\"\u003e20\u003c\/strong\u003e → 20 breaker spaces\u003c\/li\u003e\n\u003cli data-section-id=\"1bpf534\" data-start=\"370\" data-end=\"432\"\u003e\n\u003cstrong data-start=\"372\" data-end=\"378\"\u003e40\u003c\/strong\u003e → Up to 40 circuits (with approved tandem breakers)\u003c\/li\u003e\n\u003cli data-section-id=\"kmoxa1\" data-start=\"433\" data-end=\"489\"\u003e\n\u003cstrong data-start=\"435\" data-end=\"440\"\u003eL\u003c\/strong\u003e → Main lug (no factory-installed main breaker)\u003c\/li\u003e\n\u003cli data-section-id=\"1owrdc8\" data-start=\"490\" data-end=\"522\"\u003e\n\u003cstrong data-start=\"492\" data-end=\"499\"\u003e125\u003c\/strong\u003e → 125-amp bus rating\u003c\/li\u003e\n\u003cli data-section-id=\"502oqy\" data-start=\"523\" data-end=\"595\"\u003e\n\u003cstrong data-start=\"525\" data-end=\"532\"\u003ePGC\u003c\/strong\u003e → Plug-on neutral \/ ground bar \/ cover package configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"597\" data-end=\"600\"\u003e\n\u003ch3 data-section-id=\"1xn4pf1\" data-start=\"602\" data-end=\"620\"\u003e⚡ What it does\u003c\/h3\u003e\n\u003cp data-start=\"621\" data-end=\"632\"\u003eThis panel:\u003c\/p\u003e\n\u003cul data-start=\"633\" data-end=\"892\"\u003e\n\u003cli data-section-id=\"ing43e\" data-start=\"633\" data-end=\"682\"\u003eDistributes incoming power to branch circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1fx67jq\" data-start=\"683\" data-end=\"732\"\u003eAccepts \u003cstrong data-start=\"693\" data-end=\"730\"\u003eHomeline plug-on neutral breakers\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yc2dbn\" data-start=\"733\" data-end=\"822\"\u003eUses \u003cstrong data-start=\"740\" data-end=\"779\"\u003emain lugs instead of a main breaker\u003c\/strong\u003e (typically fed from upstream disconnect)\u003c\/li\u003e\n\u003cli data-section-id=\"vts591\" data-start=\"823\" data-end=\"892\"\u003eSupports up to \u003cstrong data-start=\"840\" data-end=\"892\"\u003e40 branch circuits in 20 physical breaker spaces\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"894\" data-end=\"897\"\u003e\n\u003ch3 data-section-id=\"1a97u8\" data-start=\"899\" data-end=\"918\"\u003e🏠 Typical uses\u003c\/h3\u003e\n\u003cul data-start=\"919\" data-end=\"1064\"\u003e\n\u003cli data-section-id=\"za1009\" data-start=\"919\" data-end=\"932\"\u003eSubpanels\u003c\/li\u003e\n\u003cli data-section-id=\"19lm4o8\" data-start=\"933\" data-end=\"977\"\u003eMain panels where disconnect is upstream\u003c\/li\u003e\n\u003cli data-section-id=\"1oeyl25\" data-start=\"978\" data-end=\"1013\"\u003eGarages \/ workshops \/ additions\u003c\/li\u003e\n\u003cli data-section-id=\"gje7a3\" data-start=\"1014\" data-end=\"1064\"\u003eSmall-to-medium residential electrical systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1066\" data-end=\"1069\"\u003e\n\u003ch3 data-section-id=\"1p3o9gl\" data-start=\"1071\" data-end=\"1096\"\u003e🧠 Simple explanation\u003c\/h3\u003e\n\u003cblockquote data-start=\"1097\" data-end=\"1259\"\u003e\n\u003cp data-start=\"1099\" data-end=\"1259\"\u003eThis is a \u003cstrong data-start=\"1109\" data-end=\"1259\"\u003e125-amp Square D Homeline breaker panel with 20 breaker spaces that can support up to 40 circuits, typically used as a main-lug panel or subpanel.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"1261\" data-end=\"1264\"\u003e\n\u003ch3 data-section-id=\"1ioqiu6\" data-start=\"1266\" data-end=\"1285\"\u003e🔧 Key takeaway\u003c\/h3\u003e\n\u003cul data-start=\"1286\" data-end=\"1495\"\u003e\n\u003cli data-section-id=\"1q3qwpl\" data-start=\"1286\" data-end=\"1302\"\u003e\u003cstrong data-start=\"1288\" data-end=\"1302\"\u003e125A rated\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1pw7enq\" data-start=\"1303\" data-end=\"1332\"\u003e\u003cstrong data-start=\"1305\" data-end=\"1332\"\u003e20 spaces \/ 40 circuits\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"v1h0q5\" data-start=\"1333\" data-end=\"1350\"\u003e\u003cstrong data-start=\"1335\" data-end=\"1350\"\u003eIndoor only\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"opsxi\" data-start=\"1351\" data-end=\"1441\"\u003e\n\u003cstrong data-start=\"1353\" data-end=\"1379\"\u003eMain lug configuration\u003c\/strong\u003e (not a main breaker panel unless converted with approved kit)\u003c\/li\u003e\n\u003cli data-section-id=\"crzfon\" data-start=\"1442\" data-end=\"1495\"\u003eCompatible with \u003cstrong data-start=\"1460\" data-end=\"1490\"\u003eSquare D Homeline breakers\u003c\/strong\u003e only\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SQUARE D (DIB DROP SHIP)","offers":[{"title":"Default Title","offer_id":52411464122657,"sku":"HOM2040L125PGC","price":85.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/1905\/1041\/files\/shopping_11_9604aeb7-d1c3-444e-93b2-268aa0c88562.webp?v=1777585127","url":"https:\/\/standardvmi.com\/products\/hom-indr-125a-mlo-20-40cir-wgb","provider":"Standard Plumbing Supply","version":"1.0","type":"link"}