{"product_id":"navicirc-kit","title":"NAVICIRC KIT","description":"\u003cp data-start=\"99\" data-end=\"360\"\u003eThe \u003cstrong data-start=\"103\" data-end=\"126\"\u003eNavien NaviCirc Kit\u003c\/strong\u003e is a domestic hot water recirculation solution designed to reduce wait time for hot water at faucets. It works with compatible Navien tankless water heaters and uses existing plumbing—eliminating the need for a dedicated return line.\u003c\/p\u003e\n\u003chr data-start=\"362\" data-end=\"365\"\u003e\n\u003ch3 data-section-id=\"1g7jfts\" data-start=\"367\" data-end=\"388\"\u003e⚙️ Key Features\u003c\/h3\u003e\n\u003cul data-start=\"389\" data-end=\"979\"\u003e\n\u003cli data-section-id=\"1dbfu8t\" data-start=\"389\" data-end=\"530\"\u003e\n\u003cstrong data-start=\"391\" data-end=\"419\"\u003eNo Return Line Required:\u003c\/strong\u003e\u003cbr data-start=\"419\" data-end=\"422\"\u003eUses the home’s cold water line as a return path for recirculation \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pu2bcd\" data-start=\"531\" data-end=\"617\"\u003e\n\u003cstrong data-start=\"533\" data-end=\"563\"\u003eFaster Hot Water Delivery:\u003c\/strong\u003e\u003cbr data-start=\"563\" data-end=\"566\"\u003eMinimizes water waste and wait time at fixtures\u003c\/li\u003e\n\u003cli data-section-id=\"1x08t84\" data-start=\"618\" data-end=\"775\"\u003e\n\u003cstrong data-start=\"620\" data-end=\"654\"\u003eAutomatic Temperature Control:\u003c\/strong\u003e\u003cbr data-start=\"654\" data-end=\"657\"\u003eValve closes when water reaches about \u003cstrong data-start=\"697\" data-end=\"712\"\u003e95°F (35°C)\u003c\/strong\u003e to prevent overheating \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fbwsul\" data-start=\"776\" data-end=\"879\"\u003e\n\u003cstrong data-start=\"778\" data-end=\"810\"\u003eDesigned for Navien Systems:\u003c\/strong\u003e\u003cbr data-start=\"810\" data-end=\"813\"\u003eOptimized for \u003cstrong data-start=\"829\" data-end=\"854\"\u003eNPE-A \/ NPE-A2 series\u003c\/strong\u003e tankless water heaters\u003c\/li\u003e\n\u003cli data-section-id=\"6xvonv\" data-start=\"880\" data-end=\"979\"\u003e\n\u003cstrong data-start=\"882\" data-end=\"912\"\u003eWorks with Demand Systems:\u003c\/strong\u003e\u003cbr data-start=\"912\" data-end=\"915\"\u003eCompatible with Navien HotButton for on-demand recirculation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"981\" data-end=\"984\"\u003e\n\u003ch3 data-section-id=\"1aps8o5\" data-start=\"986\" data-end=\"1010\"\u003e📦 What’s Included\u003c\/h3\u003e\n\u003cul data-start=\"1011\" data-end=\"1144\"\u003e\n\u003cli data-section-id=\"wuo8o3\" data-start=\"1011\" data-end=\"1043\"\u003eNaviCirc recirculation valve\u003c\/li\u003e\n\u003cli data-section-id=\"1y1slx7\" data-start=\"1044\" data-end=\"1076\"\u003eTwo flexible stainless hoses\u003c\/li\u003e\n\u003cli data-section-id=\"1uve6s6\" data-start=\"1077\" data-end=\"1144\"\u003eAdapters for installation \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1146\" data-end=\"1149\"\u003e\n\u003ch3 data-section-id=\"nmgiu6\" data-start=\"1151\" data-end=\"1174\"\u003e📋 Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1175\" data-end=\"1512\"\u003e\n\u003cli data-section-id=\"on28xa\" data-start=\"1175\" data-end=\"1205\"\u003e\n\u003cstrong data-start=\"1177\" data-end=\"1193\"\u003ePart Number:\u003c\/strong\u003e 30022965A\u003c\/li\u003e\n\u003cli data-section-id=\"1j095m2\" data-start=\"1206\" data-end=\"1240\"\u003e\n\u003cstrong data-start=\"1208\" data-end=\"1222\"\u003eFlow Rate:\u003c\/strong\u003e 0.53 – 1.06 GPM\u003c\/li\u003e\n\u003cli data-section-id=\"m6tqd9\" data-start=\"1241\" data-end=\"1270\"\u003e\n\u003cstrong data-start=\"1243\" data-end=\"1260\"\u003eMax Pressure:\u003c\/strong\u003e 150 PSI\u003c\/li\u003e\n\u003cli data-section-id=\"14u7o76\" data-start=\"1271\" data-end=\"1304\"\u003e\n\u003cstrong data-start=\"1273\" data-end=\"1293\"\u003eConnection Size:\u003c\/strong\u003e 1\/2\" NPS\u003c\/li\u003e\n\u003cli data-section-id=\"1bsb6cu\" data-start=\"1305\" data-end=\"1377\"\u003e\n\u003cstrong data-start=\"1307\" data-end=\"1333\"\u003eInstallation Location:\u003c\/strong\u003e Under sink (furthest fixture recommended)\u003c\/li\u003e\n\u003cli data-section-id=\"ugvtta\" data-start=\"1378\" data-end=\"1414\"\u003e\n\u003cstrong data-start=\"1380\" data-end=\"1396\"\u003eOrientation:\u003c\/strong\u003e Horizontal only\u003c\/li\u003e\n\u003cli data-section-id=\"1v3xbsc\" data-start=\"1415\" data-end=\"1438\"\u003e\n\u003cstrong data-start=\"1417\" data-end=\"1428\"\u003eWeight:\u003c\/strong\u003e ~1.1 lb\u003c\/li\u003e\n\u003cli data-section-id=\"1dlgwez\" data-start=\"1439\" data-end=\"1512\"\u003e\n\u003cstrong data-start=\"1441\" data-end=\"1454\"\u003eWarranty:\u003c\/strong\u003e Typically 3 years \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1514\" data-end=\"1517\"\u003e\n\u003ch3 data-section-id=\"t2255f\" data-start=\"1519\" data-end=\"1540\"\u003e🏠 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1541\" data-end=\"1694\"\u003e\n\u003cli data-section-id=\"1oolpov\" data-start=\"1541\" data-end=\"1586\"\u003eResidential tankless water heater systems\u003c\/li\u003e\n\u003cli data-section-id=\"1i27qni\" data-start=\"1587\" data-end=\"1642\"\u003eHomes without a dedicated recirculation return line\u003c\/li\u003e\n\u003cli data-section-id=\"101frm0\" data-start=\"1643\" data-end=\"1694\"\u003eUnder-sink installation at the farthest fixture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1696\" data-end=\"1699\"\u003e\n\u003ch3 data-section-id=\"ig4ix1\" data-start=\"1701\" data-end=\"1722\"\u003e🔁 How It Works\u003c\/h3\u003e\n\u003cul data-start=\"1723\" data-end=\"1939\"\u003e\n\u003cli data-section-id=\"1rk2dzt\" data-start=\"1723\" data-end=\"1782\"\u003eThe built-in pump in a Navien unit circulates hot water\u003c\/li\u003e\n\u003cli data-section-id=\"ueu1ni\" data-start=\"1783\" data-end=\"1862\"\u003eThe NaviCirc valve routes cooled water from the hot line into the cold line\u003c\/li\u003e\n\u003cli data-section-id=\"hegtem\" data-start=\"1863\" data-end=\"1939\"\u003eOnce hot water reaches the valve, it automatically shuts off circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1941\" data-end=\"1944\"\u003e\n\u003ch3 data-section-id=\"un2y3w\" data-start=\"1946\" data-end=\"1970\"\u003e⚠️ Important Notes\u003c\/h3\u003e\n\u003cul data-start=\"1971\" data-end=\"2199\"\u003e\n\u003cli data-section-id=\"1rskgtu\" data-start=\"1971\" data-end=\"2045\"\u003eRequires a \u003cstrong data-start=\"1984\" data-end=\"2043\"\u003ecompatible Navien unit with built-in recirculation pump\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nq7gbl\" data-start=\"2046\" data-end=\"2116\"\u003eMust be installed at the \u003cstrong data-start=\"2073\" data-end=\"2093\"\u003efurthest fixture\u003c\/strong\u003e for best performance\u003c\/li\u003e\n\u003cli data-section-id=\"tiiu5s\" data-start=\"2117\" data-end=\"2199\"\u003eNot a standalone pump—this is a \u003cstrong data-start=\"2151\" data-end=\"2164\"\u003evalve kit\u003c\/strong\u003e, not a full recirculation system\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"NAVIEN AMERICA","offers":[{"title":"Default Title","offer_id":52410767474977,"sku":"30022965A","price":96.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/1905\/1041\/files\/tRh7N1ckCrLL4RbUemK5ew0sXuZPItxRvYHSr-beAhYBDoZb1oeD7zDEw9qVgiz-e4M2LFOdxzqVOqbtjHoi5VckUBfRHYUZhNrPdgZti6MsscIT4vLs24e9ao0i3Aihbk4PjnNSpDpJ_Mljs4ufhKmGz48AyQHn3pSjxH0XU8hArmHLIBRC0EC.webp?v=1774536581","url":"https:\/\/standardvmi.com\/products\/navicirc-kit","provider":"Standard Plumbing Supply","version":"1.0","type":"link"}