{"product_id":"stick-meter-w-b-light","title":"STICK METER W\/ B-LIGHT","description":"\"\u003cu\u003eFieldpiece\u003c\/u\u003e Expandable True RMS Stick Multimeter with Backlight\u003cbr\u003eSKU: HS36\u003cbr\u003e\u003cbr\u003eOur top of the line True RMS Stick Meter, the HS36, includes the ranges you use everyday for HVAC\/R field service plus includes a bright blue backlight and True RMS. Like the rest of the HS30 series, the HS36 comes equipped with a magnetic hanger, along with detachable silicone test leads and alligator clip probe tips for remote and easy one-handed testing, as well as the full set of built-in safety features. This auto-ranging stick meter also includes a bar graph on the LCD for an analog feel. Technicians who prefer our expandable stick meters say this is the best digital multimeter for HVAC\/R field Service.\u003cbr\u003eThe HS36 works with all Fieldpiece accessory heads enabling the user to test a wider variety of parameters from a single meter. All this plus the removable tip test leads and alligator probe extensions make safe one-handed testing a snap. True RMS allows you to test true voltage and amperage on non-sinusoidal waveform lines such as those found on variable speed fan motors and more. As with all electrical testing, please read the Operator's Manual and associated safety practices thoroughly before testing and adhere to industry best practices for safety when testing any current carrying device.\u003cbr\u003eAuto Ranging\u003cbr\u003eThe HS36 is an auto ranging meter and is very accurate. For this reason, when you switch to a position on the meter that auto ranges, you're likely to see movement on the display. For example, when the dial is turned to VAC the meter will drop to the millivolts range and you'll see an \"\"m\"\" on the bottom of the LCD signifying a millivolt reading. The meter is picking up very low transient voltages in the air. Close the circuit by touching the leads together away from a voltage source. You'll see the meter zero or a very small, stable millivolt reading.\u003cbr\u003eSelecting Ranges\u003cbr\u003eFor DC voltage, set the meter to the VDC parameter instead of VAC. For all ranges choose a range just above the value you expect. If display reads \"\"OL\"\" (overload), select a higher range. If \u003cu\u003eFieldpiece\u003c\/u\u003e Expandable True RMS Stick Multimeter with Backlightdisplay shows less than three numbers, select a lower range for better resolution.\u003cbr\u003eFeatures and Benefits:\u003cbr\u003eThe HS meter series is unlike any other found in HVAC\/R. We incorporate a number of safety features, both those you can and can't see, into our meters. In addition, the HS series accepts modular test instrument accessory heads. The HS36 is the top of the line stick meter. It includes the features and benefits that technicians tell us they need to do their job easier, better and faster:\u003cbr\u003eNon-Contact Voltage\u003cbr\u003eWith the red NCV tab on the tip of the meter close to an AC voltage, press and hold the NCV button. The NCV LED will light and the beeper will beep. The closer you get to AC voltage, the louder the beep. The NCV function is sensitive enough to detect 24VAC on thermostats.\u003cbr\u003eCapacitance\u003cbr\u003eFor motor-start and motor-run capacitors. Disconnect the capacitor from power first. Short the terminals to discharge the capacitors. Disconnect any resistors that might be between the terminals of the capacitor.\u003cbr\u003eMicroamps\u003cbr\u003eFor measuring the flame diode current in a heater control.\u003cbr\u003eHigh Voltage and Continuity Indicators\u003cbr\u003eIn any VAC\/VDC range, when you touch a voltage greater than 30V, the beeper will beep and the red Hi-V LED will signal you. Be careful! The continuity beeper and green LED tell you if the circuit you're testing is open or closed.\u003cbr\u003eMIN\/MAX\u003cbr\u003ePress MIN\/MAX once to begin recording MIN and MAX. Press MIN\/MAX to select current reading's MIN or MAX. Hold down for 2 seconds to exit MIN\/MAX function.\u003cbr\u003eTemperature\u003cbr\u003ePlug any K-type thermocouple directly into the meter to measure temperature. Temperature measurement will be accurate even in fast changing environments because of excellent temperature compensation. One thermocouple is included. No adapter is required.\u003cbr\u003eBacklight\u003cbr\u003ePress the button to activate the backlight for approximately 60 seconds.\u003cbr\u003eTrue RMS\u003cbr\u003eDigital multimeters use two different types of AC sensing. The most common is average sensing, normalized to a true RMS value of a sine wave. The other is true RMS sensing. The actual true RMS value is sensed for a wave form within the limits of the crest factor. Either sensing method will give the same results on a clean sine wave but they may differ on a non-sinusoidal waveform.\u003cbr\u003eSilicone Leads with Detachable Probe Tips\u003cbr\u003eBecause the wire insulation is silicone the leads will stay flexible in cold weather and will not melt if bumped by a soldering iron. When testing electrical circuits with two hands, there is a risk that a careless mistake may complete a circuit through your body and potentially cause death or injury. Detachable probes tips and the modular design of the HS36 allow you to plug V lead tip into the top of the meter, connect an alligator lead tip to COM and ground, and perform a one-hand test more easily than most any meter on the market.\u003cbr\u003eMore Features\u003cul\u003e\n\u003cli\u003eRugged ABS case with rubberized bumpers\u003c\/li\u003e\n\u003cli\u003eBuilt-in magnetic hanger allows you to test with one hand or no-hands\u003c\/li\u003e\n\u003cli\u003eBuilt-in lead storage\u003c\/li\u003e\n\u003cli\u003eErgonomic shape fits naturally in your hand\u003c\/li\u003e\n\u003cli\u003eAuto power-off (APO) to conserve battery life\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eCompetitive Advantages:\u003cbr\u003eIt wasn't too long ago that the only multimeter you could buy was designed for lab use. Today's HVAC\/R technician can buy meters with functions and features specifically designed for field use. And, they're more rugged, convenient, and safe. Clips for one-handed testing. Loud BEEPERS and bright LEDS to warn of dangerous voltages, even in noisy environments. Magnetic hangers. Automatic HOLD and MAX so eyes stay focused on the test point. Silicone leads. Plus, modular expandability allows you to take a truckload of test instruments to the job in a bag over your shoulder.\u003cbr\u003eWhat's Included:\u003cul\u003e\n\u003cli\u003eExpandable True RMS Stick Multimeter with Backlight - HS36\u003c\/li\u003e\n\u003cli\u003e400A Amp Clamp Accessory - ACH4\u003c\/li\u003e\n\u003cli\u003eDeluxe Silicone Test Leads - ADLS2\u003c\/li\u003e\n\u003cli\u003eShort Alligator Lead Extensions - ASA2\u003c\/li\u003e\n\u003cli\u003eDeluxe Meter Case - ANC1\u003c\/li\u003e\n\u003cli\u003e9V battery (installed)\u003c\/li\u003e\n\u003cli\u003eOperator's manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eAdditional Specifications:\u003cbr\u003eTemperature\u003cul\u003e\n\u003cli\u003eRange: -30 to 1000?F (-34 to 538?C)\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1?F\/?C\u003c\/li\u003e\n\u003cli\u003eAccuracy: ?1?F, 32 to 120?F (0 to 49?C), ?1% + 1.5?F, -4 to 750?F (-20 to 399?C), ?2% + 4?F, -30 to -4?F (-34 to -20?C), ?2% + 4?F, 750 to 1000?F (399 to 538?C)\u003c\/li\u003e\n\u003cli\u003eSensor type: K-type thermocouple\u003c\/li\u003e\n\u003cli\u003eOverload protection: 60 VDC or 30 VAC rms\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eContinuity\u003cul\u003e\n\u003cli\u003eAudible indication: Less than 40 ohm\u003c\/li\u003e\n\u003cli\u003eResponse time: 500ms\u003c\/li\u003e\n\u003cli\u003eGreen LED will be on continuously\u003c\/li\u003e\n\u003cli\u003eOverload protection: 500VDC or AC rms\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eDC volts\u003cul\u003e\n\u003cli\u003eRanges: 400mV, 4000mV, 40V, 400V, 600V\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1mV\u003c\/li\u003e\n\u003cli\u003eAccuracy: ?(0.5% rdg + 2 dgt)\u003c\/li\u003e\n\u003cli\u003eInput impedance: 3 Mohm on V inputs, 10 Mohm on mV input\u003c\/li\u003e\n\u003cli\u003eOverload protection: 600VDC or AC rms\u003c\/li\u003e\n\u003cli\u003eTransient protection: 6kV for 10 micro sec\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eAC volts (50Hz - 500Hz)\u003cul\u003e\n\u003cli\u003eRanges: 400mV, 4V, 40V, 400V, 600V\u003c\/li\u003e\n\u003cli\u003eConversion: True RMS\u003c\/li\u003e\n\u003cli\u003eCrest factor: Less than or equal to 3\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1mV\u003c\/li\u003e\n\u003cli\u003eAccuracy: ?(1.2% rdg + 5 dgts) 50Hz ~ 60Hz on 400mV range ?(1.5% rdg + 5 dgts) ?(2% rdg + 5 dgts) on 600V range\u003c\/li\u003e\n\u003cli\u003eInput impedance: 3 Mohm\u003c\/li\u003e\n\u003cli\u003eOverload protection: 600V DC or AC rms\u003c\/li\u003e\n\u003cli\u003eTransient protection: 6kV for 10 micro sec\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eDC current\u003cul\u003e\n\u003cli\u003eRanges: 400 microA, 4000 microA\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1 microA\u003c\/li\u003e\n\u003cli\u003eAccuracy: ?(1.0% rdg + 2 dgt)\u003c\/li\u003e\n\u003cli\u003eVoltage burden: 1V, (8V on 4000 microA range)\u003c\/li\u003e\n\u003cli\u003eOverload protection: 500V DC or AC rms\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eResistance\u003cul\u003e\n\u003cli\u003eRanges: 400 ohm, 4 k ohm, 40 k ohm, 400 k ohm, 4 M ohm, 40 M ohm\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1 ohm\u003c\/li\u003e\n\u003cli\u003eAccuracy: ?(1.0% rdg + 4 dgts) on 400 ohm to 400 k ohm ranges ?(1.5% rdg + 4 dgts) on 4 Mohm range ?(3.0% rdg + 5 dgts) on 40 Mohm range\u003c\/li\u003e\n\u003cli\u003eOpen circuit volts: -0.45VDC typical, (-1.2VDC on 400 ohm range)\u003c\/li\u003e\n\u003cli\u003eOverload protection: 500VDC or AC rms\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eCapacitance\u003cul\u003e\n\u003cli\u003eRange: 400 microF\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1 microF\u003c\/li\u003e\n\u003cli\u003eAccuracy: ?(3% rdg + 5 dgts)\u003c\/li\u003e\n\u003cli\u003eOverload protection: 500V DC or AC rms\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eFrequency\u003cul\u003e\n\u003cli\u003eRanges: 4k, 40k, 400k, 4M, 40MHz\u003c\/li\u003e\n\u003cli\u003eResolution: 1Hz\u003c\/li\u003e\n\u003cli\u003eAccuracy: ?(0.1% rdg + 3 dgts)\u003c\/li\u003e\n\u003cli\u003eSensitivity: 10Hz ~ 4MHz: \u0026gt; 1Vrms, 4MHz ~ 40MHz: \u0026gt; 2Vrms, \u0026lt;5Vrms\u003c\/li\u003e\n\u003cli\u003eMinimum pulse width: \u0026gt; 25ns\u003c\/li\u003e\n\u003cli\u003eDuty cycle limits: \u0026gt; 30% and \u0026lt; 70%\u003c\/li\u003e\n\u003cli\u003eOverload protection: 500VDC or AC rms\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003eField ?F calibration\u003cbr\u003eFor accuracies of ?1?F, calibrate to a known temperature. A glass of stabilized ice water is very close to 32?F (0?C) and is usually very convenient but any known temperature can be used.\u003cbr\u003e\u003cbr\u003e**\u003cbr\u003e\"","brand":"FIELDPIECE INSTRUMENTS","offers":[{"title":"Default Title","offer_id":52411298414881,"sku":"HS36","price":335.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/1905\/1041\/files\/HS36.PART1.jpg?v=1772506750","url":"https:\/\/standardvmi.com\/products\/stick-meter-w-b-light","provider":"Standard Plumbing Supply","version":"1.0","type":"link"}